overview
Images Available
key benefits, specs and more...
v Micro controller based
Smart hybrid technology
v Pure sine wave output
v Dual Chargers (Built-in
MPPT Solar controller and AC mode battery Charger)
v Parallel Mode: Upto 6nos (1-PH) and Upto 9nos (3-PH)
v With Two charging mode: AC charging mode and solar charging mode, solar charging
priority
v Can Choose Two work mode: Solar-Grid-Battery, Solar-Battery-Grid, can choose from
LCD display
v Intelligent detecting function: This system microprocessor can continually
on-line detect power status, breaker status and all the working status of the
circuit.
v Excellent load feature: It is completely capable to load from 0-100% while no
need to change to bypass, which make sure the output reliable.
v Intelligent communication-URL based remote monitoring and
operation: With RS232 and
RS485 standard collocation, optional SNMP and dry contact
v Perfect protection: Input/output over/low voltage protection, input surge
protection, phase sequence protection, battery over charge/discharge
protection, short circuit protection, over-temperature protection and so on, as
well as alarm function.
Selectable battery inspection module: Can test the single parameter and display on the LCD, battery failure will immediately alarm and inform the administrator.
Solar power stations
Home solar power systems
Industrial Solar power storage
DC wind turbine stations
Healthcare/Banking/Commercial applications
Model |
HSP10K48SW-LCD |
Rated Power |
10KVA/10KW |
INPUT
AC |
|
Nominal Input Voltage |
220/230/240V
AC |
Low Loss Voltage |
170V
AC +/- 7V (UPS mode) |
90V
AC +/- 7V (Appliances mode) |
|
Low loss return Voltage |
180V
AC +/- 7V (UPS mode) |
100V
AC +/- 7V (Appliances mode) |
|
High loss Voltage |
280VAC +/- 7V |
High loss Return Voltage |
270VAC +/- 7V |
Max AC input voltage |
300V
AC |
Frequency Range |
50Hz/60Hz
(auto sensing) |
Low loss frequency |
40+/-1Hz |
Low loss return frequency |
42+/-1Hz |
Hig loss frequency |
65+/-1Hz |
High loss return frequency |
63+/-1Hz |
Output Short circuit Protection |
Line
Mode: Circuit Breaker |
Battery
Mode: Electronic Circuits |
|
Efficiency |
>97% |
OUTPUT
AC |
|
AC Voltage Regulation |
220/230/240V
AC +/- 5% |
Rated Output Power |
10KVA/10KW |
Output Voltage Waveform |
Pure
Sine wave |
Output Frequency |
50Hz/60Hz
(auto sensing) |
Surge Power |
30000VA |
Efficiency |
95-97% |
Over Load protection |
5sec
@>150% load; 10sec@110~150% load |
Nominal DC input Voltage |
48V
DC |
Cold Start Voltage |
46.0V
DC |
Low
DC Warning Voltage |
|
@load < 20% |
44.0V
DC |
@ 20% < load < 50% |
42.8V
DC |
@ load > 50% |
40.4V
DC |
Low
DC Warning Return Voltage |
|
@load < 20% |
46.0V
DC |
@ 20% < load < 50% |
44.8V
DC |
@ load > 50% |
42.4V
DC |
Low
DC Cut-off Voltage |
|
@load < 20% |
42.0V
DC |
@ 20% < load < 50% |
40.8V
DC |
@ load > 50% |
38.4V
DC |
High DC Recovery Voltage |
58V
DC |
High DC Cut-off Voltage |
62V
DC |
No Load Power Consumption |
<5W |
Saving Mode Power Consumption |
<15W |
Transfer Time |
6-10mSec |
Efficiency |
93~
97% |
Charger
Mode Specs |
|
Battery Voltage |
48V
DC |
Floating Charge Voltage |
54V
DC |
Overcharge Protection |
60V
DC |
Maximum Charge Current |
120A |
Bulk Charging Voltage (Flooded
Battery) |
58.4V
DC |
Bulk Charging Voltage (AGM/GEL
battery) |
56.4V
DC |
Charging Algorithm |
3-Stage
(CC-CV-Floating) |
Solar
Charging Mode Specs |
|
Maximum PV Array Power |
2nos
of 5000Wp (10,000Wp) |
MPPT Range @ Operating Voltage |
120V
DC to 450V DC |
Maximum PV Array Open Circuit
Voltage |
500V
DC |
Maximum Charging Current |
160A |
Maximum Efficiency |
98% |
Battery Voltage Accuracy |
+/-
0.3% |
PV Voltage Accuracy |
+/-
2V |
Standby Power Consumption |
2Watts |
Charging Algorithm |
3-Stage
(CC-CV-Floating) |
General
Specs |
|
Dimension (DxWxH-mm) |
420x562x155 |
Net Weight (kgs) |
27Kgs |
Humidity |
5% to
95% Relative Humidity (non-condensing) |
Operating Temperature |
0degC
to 55deg C |
Storage Temperature |
-15degC
to 60degC |
Parallel Compatibility |
Upto
6nos |
Communication |
RS232
Cable along with monitoring software included |
Dry contact for remote management |
Yes.
Ability to monitor Power OFF/On, LOW DC, Battery voltage, charge status etc |
Quality
Standards |
|
Disturbance at Mains Terminals |
EN61000-6-3:2007+ A1: 2011+
AC:2012 |
Radiated Disturbance |
EN61000-6-3:2007+ A1: 2011+
AC:2012 |
Harmonic Current Emission |
EN61000-3-12:
2011 |
Voltage fluctuations & flickering |
EN61000-3-11:
2000 |
Electrostatic Discharge (ESD) |
IEC
6100-4-2:2008 |
Radio-frequency & continuous
radiated disturbances |
IEC
6100-4-3:2006 + A1:2007 + A2:2010 |
EFT/B Immunity |
IEC
6100-4-4:2012 |
Surge immunity |
IEC
6100-4-5:2014 |
Conducted RF immunity |
IEC
6100-4-6:2013 |
Power frequency magnetic field |
IEC
6100-4-8:2009 |
Voltage DIP, >95% reduction |
IEC
6100-4-11:2004 |
Voltage DIP, >30% reduction |
IEC
6100-4-11:2004 |
Voltage Interruption |
IEC
6100-4-11:2004 |
EU Low voltage directives (LVD) |
EN62109-1:
2010, EN62109-2:2011 |
EU Electromagnetic compatibility (EMC) |
EN62040-2:2006,
EN6100-3-2:2014, EN6100-3-3:2013 |
Quality Certification |
ISO9001:2015,
ISO14001:2015, CE, RoHs |