overview
Magnizon’s HG series 6KVA /48V DC operated Smart DC-to-AC
inverter with auto line-to-battery transfer and integrated Battery charge,
serving as an extended run UPS, a standalone power source or an automotive
inverter. HG series Smart inverter supplies power from AC power and DC source.
When AC cable is connected to a wall socket, utility power goes to connected
equipment(s) and/or charges the battery set via charging system. In battery
mode, Smart inverter automatically converts battery energy into AC power for
backing up the connected devices. Large LCD displays real time information
along with operational schemes, and can also display error codes for easy
repair and maintenance. Reliable transformer less IGBT based design and
frequency controlled pure sine wave output power, very much compatible to all
domestic loads: refrigerators, TV’s, Computers, and power tool and battery
chargers. Smart micro controller based 3-stage built in charging system
properly charge and maintain battery bank.
Images Available
key benefits, specs and more...
- 48V DC or 220/230/240V AC input; 220/230/240V, 50 /60Hz Pure sine ware output
- 6000VA continuous output with double boost capacity
- Microprocessor controlled Smart volume design
- Built in 10~35A Smart Utility based battery charger
- Automatic line-to-battery switchover
- High efficient DC-to-AC conversion, minimizing energy loss
- Rack design & wall-mounted design for flexible installation
- Intelligent 3-stage charger control for efficient charging and preventing overcharge of battery
- Auto restart while AC recovery
- User-friendly LCD+LED indications
- Multiple protection: low battery alarm, low battery shutdown, over
- charged protection, overload protection, over temperature protection, short circuit protection
- With the environmental temperature control charge management
- Quiet, high efficiency operation, high surge capacity and low idle current
- CE Safety
- Compatible to mains voltage or generator power
- Auto restart while AC is recovering
- Overload, over temperature and battery deep discharge protection
- Versatile inverter/charger with pure sine wave system with seamless transfer switching serves as an automotive inverter for RVs, trucks, standalone alternative power source with high end back up times with various battery technologies (VRLA, GEL, Deep cycle, Ni-Cd and many more)
- Off-grid and On-grid applications using external MPPT smart controllers
- Home and small office applications
- Remote closets and small computer room applications.
- Petrochemical application
- Critical applications where ever higher reliability is needed
- SMB requirements
- Remote closets and small computer room applications.
Model |
HG6048SW-LCD |
Rated Power |
6000VA |
INPUT AC |
|
Nominal Input Voltage |
220/230/240V AC |
Low Loss Voltage |
170V AC +/- 7V (UPS mode) |
90V AC
+/- 7V (Appliance mode) |
|
Low loss return Voltage |
180V AC +/- 7V (UPS mode) |
100V AC
+/- 7V (Appliance mode) |
|
High loss Voltage |
280VAC +/- 7V |
High loss Return Voltage |
270VAC +/- 7V |
Max AC input voltage |
300V AC |
Frequency Range |
50Hz/60Hz (auto sensing) |
Low loss frequency |
40+/-1Hz |
Low loss return frequency |
42+/-1Hz |
High loss frequency |
65+/-1Hz |
High loss return frequency |
63+/-1Hz |
Efficiency |
>97% |
OUTPUT |
|
AC Voltage Regulation |
230V AC +/- 5% |
Rated Output Power |
6KVA/4.8KW |
Output Voltage Waveform |
Pure Sine wave |
Output Frequency |
50Hz/60Hz (auto sensing) |
Surge Power |
6000VA |
Efficiency |
95-97% |
Over Load protection |
5sec @>150% load; 10sec@110~150% load |
Nominal DC input Voltage |
48V DC |
Cold Start Voltage |
46.0V DC |
Low DC Warning Voltage |
|
@load < 20% |
44.0V DC |
@ 20% < load < 50% |
42.8V DC |
@ load > 50% |
40.4V DC |
Low DC Warning Return Voltage |
|
@load < 20% |
46.0V DC |
@ 20% < load < 50% |
44.8V DC |
@ load > 50% |
42.4V DC |
Low DC Cut-off Voltage |
|
@load < 20% |
42.0V DC |
@ 20% < load < 50% |
40.8V DC |
@ load > 50% |
38.4V DC |
High DC Recovery Voltage |
58V DC |
High DC Cut-off Voltage |
62V DC |
No Load Power Consumption |
<20W |
Saving Mode Power Consumption |
<10W |
Transfer Time |
6-10mSec |
Efficiency |
90~93% |
Charge Mode Specs (AC charger) |
|
Battery Voltage |
48V DC |
Floating Charge Voltage |
54V DC |
Overcharge Protection |
62V DC |
Maximum Charge Current |
35Amp |
Bulk Charging Voltage (Flooded Battery) |
58.4V DC |
Bulk Charging Voltage (AGM/GEL battery) |
56.4V DC |
Charging Algorithm |
3-Stage (CC-CV-Floating) |
Display Indicators |
|
AC/DC mode |
Displays output power, Output Voltage etc |
Battery Mode |
Yes. Battery symbol flickers every one sec |
Battery |
Displays Battery charge status |
Fault |
Displays fault codes (refer the service manual) |
Audible Alarm |
|
Low Battery at Battery Mode |
Sounding every 2 seconds |
Over Load |
Sounding every 0.5seconds |
Faults |
Continuous sounding |
Protection |
|
Battery deep discharge Protection |
Yes |
Battery Over charge protection |
Yes |
Inverter Over load protection |
Yes |
Over temperature protection |
Yes |
General Specs |
|
Dimension (WxHxD-mm) |
430*350*105mm |
Net Weight (kgs) |
8.5kgs |
Humidity |
5% to 95% Relative Humidity (non-condensing) |
Operating Temperature |
0degC to 40deg C |
Storage Temperature |
-15degC to 50degC |
Cooling |
Forced air, variable
speed fan |
Noise Level |
less than 60dB |
Quality/Safety standards |
ISO9001:2015/ISO14001:2015 |
Safety |
EMC/CE/ROHS |
Certification/Confirmity |
|
Disturbance at Mains Terminals |
EN61000-6-3:2007+ A1:
2011+ AC:2012 |
Radiated Disturbance |
EN61000-6-3:2007+ A1:
2011+ AC:2012 |
Harmonic Current Emission |
EN61000-3-12: 2011 |
Voltage fluctuations & flickering |
EN61000-3-11: 2000 |
Electrostatic Discharge (ESD) |
IEC 6100-4-2:2008 |
Radio-frequency & continuous radiated disturbances |
IEC 6100-4-3:2006 + A1:2007 + A2:2010 |
EFT/B Immunity |
IEC 6100-4-4:2012 |
Surge immunity |
IEC 6100-4-5:2014 |
Conducted RF immunity |
IEC 6100-4-6:2013 |
Power frequency magnetic field |
IEC 6100-4-8:2009 |
Voltage DIP, >95% reduction |
IEC 6100-4-11:2004 |
Voltage DIP, >30% reduction |
IEC 6100-4-11:2004 |
Voltage Interruption |
IEC 6100-4-11:2004 |