Magnizon-Solar Water Pumping System, 5.5KW

SVD-007K3

  • More Accurate Motor Auto-tuning
  • Advanced open loop vector control
  • Suitable for submersible/surface mount/ synchronous /Asynchronous type water pumps/motors
  • Perfect voltage and current control, reducing the fault protection times
  • Solar and National grid/Generator compatible
  • Multiple braking modes and instant stopping
  • VF and Sensor-less Vector Control
  • Up to 0.5Hz/150% starting torque
  • LED Key pad for the parameters configuration at field
  • Standard C3 filters; Optional C2 filters
  • Accurate parameters auto tuning and better motor drive
  • Simple water supply function
  • CE Safety certified

Overview

Magnizon SVD-007K3 solar pump inverter, efficiently drives the pump motors by advanced maximum Power Point Tracking (MPPT) technology. Magnizon solar inverters support solar panel input, and AC main power or generator input. It can work 24hours with enough power support. 100% compliance with CE safety/EN/IEC 60068-2-27. Compatible with all kinds of motors & pumps including asynchronous & synchronous, submersible and surface mount.

Applications

Existing AC motor based systems can be used: Conventional AC induction motors are generally used for water pumping system, so with this advancement in technology there is no need to replace the existing pump/motor/pipes/cables. Simply user can add Solar Panel & controller to run existing AC motor during day time and at night Grid power can be used (dual input systems).

Key Features

  • With no water alarm, timing to restart functions. When the pool has no water, the will stop, and then it will restart after interval set or water level raises to safe level.
  • When the pool is full, the solar inverter automatically stops, and it will show it in solar inverter`s panel.
  • Reliable: Solar inverter power supply are seldom used in the moving parts; the work is reliable
  • Safety: No other public nuisance. Don't have any solid, liquid and gas harmful substances, absolutely environmental protection.
  • Easy installation and maintenance, suitable for unattended or automatic running needs, etc
  • Good compatibility, Solar power generation can be used with other energy, also can according to the need to make the solar system easily expanded
  • Input voltage: DC 100V~310V (1-ph pumps) & DC 100V~600V (3-Ph pumps)
  • Input frequency range: 0-400Hz
  • Control mode: V/F control mode
  • Carrier frequency setting: 1kHz-15kHz.
  • Input frequency resolution: digital setting, 0.01Hz, analogue setting, Max frequency×0.1%
  • Starting torque: 0.5Hz/150%
  • Overload capacity: 150% Rated current-60s, 180% Rated current-10s
  • Torque boost :0.1%-50.0%
  • V/F curve: liner type, multipoint type
  • JOG control: JOG frequency range, 0.00Hz-50.00Hz, JOG acceleration and deceleration time 0.0s-6500.0s
  • PLC Multi-speed running: By built-in PLC
  • Built-in PID: Easy to realize process control closed loop control system
  • Automatic voltage regulation(AVR): When voltage change, it can automatically maintain constant output voltage
  • Over voltage and over current loss of speed control: During the inverter running, the current automatic voltage limit, to prevent frequent trip through the pressure
  • Communication methods: RS-485

Specifications

STANDARD FUNCTION
Maximum frequency Vector control: 0-650 Hz, V/F control: 0-3200 Hz
Carrier frequency 0.5-16 kHz, carrier frequency is automatically adjusted based on the load features.
Frequency resolution Digital setting: 0.01 Hz, Analog setting: maximum frequency x 0.025%, Sensor less flux vector control (SFVC), Closed-loop vector control (CLVC)
Control mode Voltage/Frequency (V/F) control
Startup torque G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC), P type: 0.5 Hz/100%
Speed range 1:100 (SFVC), 1:1000 (CLVC)
Speed stability accuracy ± 0.5% (SFVC), ± 0.02% (CLVC)
Torque control accuracy ± 5% (CLVC)
Overload capacity G type: 60s for 150% of the rated current, 3s for 180% of the rated current, P type: 60s for 120% of the rated current, 3s for 150% of the rated current
Torque boost Fixed boost, Customized boost 0.1%-30.0%
V/F curve Straight-line V/F curve, Multi-point V/F curve, N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square), Two types: complete separation; half separation, Straight-line ramp
Ramp mode S-curve , Four groups of acceleration/deceleration time with the range of 0.0-6500.0s
DC braking DC braking frequency: 0.00 Hz to maximum frequency, Braking time: 0.0-36.0s, Braking action current value: 0.0%-100.0%
JOG control JOG frequency range: 0.00-50.00 Hz, JOG acceleration/deceleration time: 0.0-6500.0s
Onboard multiple preset speeds Support up to 16 speeds via the simple PLC function or combination of DI terminal.
Onboard PID Embedded programmable PID controller to support closed loop control
Auto voltage regulation (AVR) It can keep constant output voltage automatically when the mains voltage changes.
Over voltage/current stall control Automatic voltage and current regulation to avoid frequently tripping over voltage/current protection
Torque limit and control Automatic torque control to avoid frequently tripping over voltage/current protection, Torque control can be implemented in the CLVC mode.
Rated AC Input Voltage Range Rated Voltage -15%~+15%
Rated AC Frequency 50Hz/60Hz+/-5%
Rated DC input voltage Range 220/230V Model: 180~400Vdc 380V/440V Model: 350~800Vdc
CAPACITY
Capacity 5.5 KW
INPUT
Voltage 1-Ph 230V +/-10%, DC input 180-300V
ENHANCED FUNCTION
High performance high-performance current vector control technology.
Dynamic MPPT Function Automatic control the output power to track the maximum power point of the solar panel
Power dip ride through Control to maintain running upon short interval power blackout or power dip
Rapid current limit It helps to avoid frequent overcurrent faults of the AC drive.
Virtual I/Os Five groups of virtual DI/Dos can realize simple logic control.
Timing control Time range: 0.0?6500.0 minutes
Multi-motor switchover Four motors can be switched over via four groups of motor parameters
Multiple communication protocols Supports communication via Modbus-RTU, PROFIBUS- DP
Motor overheat protection The optional I/O extension card enables AI3 to receive the motor temperature sensor, input (PT100, PT1000) so as to realize motor overheat protection
Protection type Line supply overvoltage and under voltage safety circuits for drive, Line supply phase loss safety function, for three phases supply for drive, Motor phase breaks for drive, Overcurrent between output phases and earth (on power up only) for drive, Overheating protection for drive, Short-circuit between motor phases for drive, Thermal protection for motor, Input phase breaks for drive
Dielectric strength 2410 V DC between earth and power terminals, 3400 V AC between control and power terminals
Insulation resistance >= 500 mOhm at 500 V DC for 1 minute
Local signalling 1 LED (red) signal for drive voltage, Four 7-segment display units signal for CANopen bus status
Time constant 5 ms for reference change
Frequency resolution 0.1...100 Hz for analog input, 0.1 Hz for display unit
Multiple encoder types Supports various encoders such as differential encoder, open-collector encoder,resolver, UVW encoder, and SIN/ COS encoder
OUTPUT
Rated current (A)** 13/17
OPERATIONAL PARAMETERS
Running command source Operation panel, Control terminals, Serial communication port
Frequency source Up to 10 frequency sources, such as digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. various ways to switchover between sources
Auxiliary frequency source Up to 10 auxiliary frequency sources. Support fine tuning of auxiliary frequency and frequency synthesis.
Input Control Terminal 5 digital input (DI) terminals, one supports up to 100 kHz high-speed pulse input, 2 analog input (AI) terminals, one supports 0-10 V voltage input and the other supports 0-10 V voltage input or 4-20 mA current input, Expanding capacity: 5 DI , 1 AI supports -10-10 V voltage input and also supports PT100\PT1000
Output terminal 1 high-speed pulse OP terminal (oc ) supports 0-100 kHz square wave signal output, 1 digital output (DO) terminal 1 relay output terminal, 1 analog output (AO) terminal that supports 0-20 mA current output or 0 to 10 V voltage output, Expanding capacity: 1 DO , 1 relay output , 1 AO supports 0-20 mA current or 0-10 V voltage output
DISPLAY AND OPERATION ON THE OPERATIONAL PANEL
LED display 5 digit LED display ,with indicators shows system status & parameters
Key locking and function selection locking the keys and define the function range of some keys so as to prevent mis operation.
Protection mode Motor short-circuit detection at power-on, input/output phase loss protection, overcurrent protection, Overvoltage protection, under-voltage protection, overheat protection and overload protection
Optional parts LCD operation panel, braking unit, I/O extension card 1, I/O extension card 2, user programmable card, RS485 communication card, PROFIBUS-DP communication card, differential input PG card, UVW differential input PG card, resolver PG card and OC input PG card
PHYSICAL DETAILS
Gross Weight (kg.) 4.8
External Size (H*W*D) (mm) 280*145*179
Package Size (H*W*D) (mm) 352*226*278
ENVIROMENT
Installation location Indoor use, avoid direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt.
Altitude Up to 4000m , de-rated needed above 1000 m
Ambient temperature -10°C to +50°C , de-rated needed above 40°C
Humidity Less than 95%RH, without condensing
Vibration Less than 5.9 m/s2 (0.6 g)
Storage temperature -20°C to +60°C
IP level IP20
Pollution degree PD2
Power system TN , TT
Warranty 2 years
CERTIFICATIONS
Electromagnetic compatibility 1.2/50 µs - 8/20 µs surge immunity test - test level 3 conforming to IEC 61000-4-5:2014, Electrical fast transient/burst immunity test - test level 4 conforming to IEC 61000-4-4:2012, Electrostatic discharge immunity test - test level 3 conforming to IEC 61000-4-2:2009, Radiated radio-frequency electromagnetic field immunity test - test level 3 conforming to IEC 61000-4-3:2006
IEC Standards EN61800-5-1, EN61800-3:2004+A1:2012, EN55011:2016, EN61000-3-2:2014, EN61000-4-4:2012, EN61000-4-8:2010, EN61000-4-6:2014, IEC62253:2011; EN62253:2012
Quality Standards ISO9001:2015, ISO14001, RoHs, CE

Similar Products

SVD-001KS

Magnizon SVD-001KS solar pump inverter, efficiently drives...

SVD-002KS

Magnizon SVD-002KS solar pump inverter, efficiently drives the p...

SVD-003K3

Magnizon SVD-003KS solar pump inverter, efficiently drives the...

SVD-005K3

Magnizon SVD-005K3 solar pump inverter, efficiently drives the p...

SVD-010K3

Magnizon SVD-010K3 solar pump inverter, efficiently drives the ...

SVD-015K3

Magnizon SVD-015K3 solar pump inverter, efficiently drives the p...

SVD-020K3

Magnizon SVD-020K3 solar pump inverter, efficiently drives the p...

SVD-025K3

Magnizon SVD-025K3 solar pump inverter, efficiently drives the p...

SVD-030K3

Magnizon SVD-030K3 solar pump inverter, efficiently drives the pum...

SVD-040K3

Magnizon SVD-040K3 solar pump inverter, efficiently drives the pu...

SVD-050K3

Magnizon SVD-050K3 solar pump inverter, efficiently drives the pu...

SVD-060K3

Magnizon SVD-060K3 solar pump inverter, efficiently drives the pump...

SVD-075K3

Magnizon SVD-075K3 solar pump inverter, efficiently drives the pum...

SVD-100K3

Magnizon SVD-100K3 solar pump inverter, efficiently drives the pum...

Optional Products